Place of Origin:
China
Brand Name:
YunYi
Certification:
CE,ROHS
Model Number:
YUNYI-ZFG
Contact Us
Description Electromagnetic flow meter for Sewage Pipeline Cement Slurry and Urban water use
The intelligent electromagnetic flowmeter consists of two main components: a sensor and a converter. Its working principle is based on Faraday's law of electromagnetic induction.
Detailed Images
Specification Sewage pipeline cement slurry flowmeter electromagnetic flowmeter with sand
Conductivity Range | The measured fluid condutivity≥5μs/cm |
Load Resistance | 0 ~ 10mA 0 ~ 1.5KΩ |
Current Output | 4 ~ 20mA 0 ~ 750KΩ |
Digital Frequency Output | Transistor output frequency limit can be set with optical isolation within 1~5000Hz bidirectional open-collector output. External power supply is turned ≤35V maximum collector current of 250mA |
Power Supply | AC 220V Or DC 24V |
Length Of Straight Pipe Requirements | Up Stream≥5DN, Down Stream≥2DN |
Connection | are used between the meter and piping flange connection, flange dimensions shall comply with the provisions of GB11988 |
Explosion Levels | Exd II BT4 |
Protection Class | IP65, Special Order up to IP68 |
Ambient Temperature | -25℃ ~ +60℃ |
Relative Humidity | 5% ~ 95% |
Total Power Consumption | Less Than 20W |
Dimension
Feature
The sensor adopts overall welding structure, good sealing
Selection
Installation:
Send your inquiry directly to us